1. In the process of using the coil spreader, if the rotary lock rolling is not sensitive or in place, check the adjusting nut, and then check the following parts:
2. If the tension spring of the pawl is damaged, it should be replaced;
3. Whether the transmission organization is stuck or not, if it is not smooth, smooth oil (or grease) should be added at the active joint of the transmission organization. If the guide pin is too tight, loosen the nut properly. If the connection is loose, the transmission pipe or other rod is deformed, it should be corrected;
4. Whether the stretching amount of the buffer tension spring is too small, if it is too small, the length of the wire rope connected with the buffer tension spring should be shortened.
5. During operation, the paint of indication mark on the indicator board of steel coil spreader should be prevented from falling. Once found, it is necessary to timely supplement the paint with the original indication mark.
6. For the wire rope on the steel coil spreader, the floor should be clean and coated with smooth oil or grease, especially at the bend of the wire rope.
|
|